Milwaukee MW102 Portable pH Meter with Separate Probes
Compare the external SE220 electrode and separate temperature probe if replaceable cabled parts are preferable.
Read the differences ↗Apera Instruments · Temperature & pH
An integrated pocket pH and temperature tester with pH 4.00/7.00 buffers, lanyard and carrying case.
Price & purchase ↓
The equipment in use
The PH20 puts the sensor and display in one pocket instrument, without separate probe cables. The display shows pH and temperature and indicates when the reading has stabilized. Choose this format for a compact testing kit when 0.1 pH resolution and declared±0.1 pH accuracy suit the measurement you need.
The selected Regular Kit includes pH 4.00 and 7.00 buffers, a lanyard, case and four AAA batteries. The meter supports one to three calibration points; the third buffer is a separate purchase. Apera starts calibration at pH 7.00 and uses the second buffer for the appropriate measurement range.
The measurement and ATC ranges are 0–50°C, while the manual advises avoiding samples above 113°F/45°C or below 41°F/5°C to reduce error and probe wear. Those are different specifications. Temperature compensation is not permission to place the tester into boiling wort.
The pH probe is non-replaceable, which matters when comparing long-term maintenance with an external-probe meter or a replaceable-tip stick. Apera specifies clean-water rinsing before and after tests and different storage arrangements for frequent use and periods longer than a month. Storage solution is a separate requirement from the two calibration buffers.
The selected reference
Before and during use
Choose the compact integrated format if its resolution and accuracy suit the task.
Consider the fixed probe and separate storage-solution requirement when comparing ownership and maintenance.
Rinse the probe with clean water before and after tests, as Apera directs; do not rub the glass membrane.
For daily/weekly use, Apera specifies a moist cap or pH 4 buffer storage with the cap tightly closed.
For storage longer than one month, Apera specifies its 3 M KCl soaking solution in the probe cap to the fill line.
Do not store the probe immersed in pure water; the manual distinguishes rinsing water from storage solution.
Connections & scope
Questions about this product
The selected kit supplies pH 4.00 and 7.00. The manual identifies pH 10.01 as a separate purchase if needed for the intended calibration range.
The maker identifies the PH20 pH probe as non-replaceable. Compare an external-probe or replaceable-electrode model if that is a priority.
No. Apera distinguishes clean-water rinsing from probe storage and specifies 3 M KCl solution for periods longer than a month.
A different choice for a different need

Compare the external SE220 electrode and separate temperature probe if replaceable cabled parts are preferable.
Read the differences ↗